Technical Statement
Product Description
- Surface-mounted or concealed installation.
-
Motorised opening and closing of
windows and skylights.
- For smoke exhaust and natural
ventilation.
-
Programmable electronic shut-down (preventing defect in case of force overload).
- High-precision synchronised electronics
for running 2 or multiple drives simultaneously.
- Low operating noises (acoustic decoupling
of drive components).
-
Corrosion protected (steel chain with
rigid backing and lubrication).
-
High-speed function (HS) in fire operation.
- Adjustable, multi-stage anti-pinch protection system.
-
Gasket protection (relief of pressure
on window gaskets).
-
Easy installation (polarity reversal
protection connector system).
- Open bus communication via ACB
(Advanced Communication Bus) to integrate with building management system.
-
Custom configuration (D+H software SCS).
Scope of use
Natural Ventilation: Designed to enhance natural ventilation in buildings, contributing to architectural sustainability.
Smoke Relief: Designed for smoke relief and life safety, meeting fire engineering requirements.
Applications: Suitable for commercial, educational, industrial, and residential sectors.
This system is for projects that prioritise both natural ventilation and smoke control, ensuring compliance with sustainability and safety standards.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause C5 Access and safety for fire fighting operations: Performance C5.6(a), C5.6(c), C5.7(b)
The chain actuators have been tested in accordance of relevant codes of practise for life safety applications.
- Clause G4 Ventilation: Performance G4.3.1
The ability to open/close automated windows to allow natural ventilation to occur.
The system is controlled by various weather sensors to maximise indoor air quality.
Internal & external temperature sensors / Co2 monitoring / wind, speed & directional sensor / rain sensor / BMS integration.
- Clause H1 Energy efficiency : Performance H1.3.1, H1.3.3(a)
Adding sustainability and natural ventilation to the building envelope
Notes
C5.6(a) - The purpose of the chain actuators are to prevent smoke logging by opening high level windows/skylights to exhaust smoke out the building, creating a path for the emergency team to fight the fire.
C5.6(c) - Providing smoke relief and clear passage
C5.7(b) - The control panel operating the chain actuators are provided with controls to operate the smoke system in emergency applications.
G4.3.1 - The chain actuator provides natural ventilation into the building at optimum times by the use of weather sensors
H1.3.1 - The chain actuator close the building during high winds / rain / high temperatures
H1.3.3(a) - The allowance of providing night time purging through automated windows.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
NZS 4211:1985 Performance of windows
DIN EN 12101-2 Smoke and heat control systems - Part 2; Specification for natural smoke and heat exhaust ventilators
AS/NZS 1170.2:2011 Ultimate Strength Performance
NZBC H1/AS1-AS2 / NZBC H1/VM1-VM2 Natural ventilation
AS/NZS 1530.7:1998 / EN 12101.2 Smoke ventilation
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
Natural Ventilation: Designed to enhance natural ventilation in buildings, contributing to architectural sustainability.
Smoke Relief: Designed for smoke relief and life safety, meeting fire engineering requirements
Applications: Suitable for commercial, educational, industrial, and residential sectors.
This system is for projects that prioritise both natural ventilation and smoke control, ensuring compliance with sustainability and safety standards.
Installation requirements
Install chain drive actuators in accordance with Manufacturer/Supplier details and installation instructions, and to comply with the reviewed shop drawings and installation details including sealant, seals and fixing positions. Carry out the fixing, installation and fitting the chain drive actuators to finish rigid, true to line and face and square on the window in accordance with manufacturer/supplier requirements.
Do not commence installation unless all preparatory work is of the required standard. Pre-drill holes on the window aluminium surface where the side and sash brackets are to be installed. Install the brackets with counter sink screws.
Make sure chain drive actuators are plumb and securely fixed to window with the correct fixings
Maintenance requirements
Operate the window system to confirm the actuator is driving the window to a fully open and fully closed position.
Make sure all fixings are securely fastened and there is no physical movement on the chain drive actuators
If you notice any moss, remove it as well using a wet sponge.
Use a mild detergent and warm water and remove grime, salt, dust or other dirt using a soft brush
Warrantees
3 years manufactures warranty
5 years installation warranty
Environmental
Corrosion protected, hardened steel chain with rigid backing and lifetime lubrication
Colour white aluminium (RAL9006)
Please contact EBSA for EPD Declaration
Quality Assurance
 |
ISO 9001 (Quality Management) |
Relationships
 |
IFT Rosenheim
M-EPD-AZR-GB-103 |
Building Product Information Requirements
Manufacturer
Legal Trading Name:
D+H Mechatronic AG
Contact Number/s:
+494 05300390
Importer
Legal Trading Name:
EBSA NZ Limited
Business Email:
sales@ebsa.co.nz
Contact Number/s:
09 8840025
Product Identifier
CDC-0252-1-ACB, VCD0203, VCD0204, VCD0204/K
Warnings