Compliance Statement
Scope of Use
MetaPan P™ metal ceiling tiles are designed to lay into standard Rondo Donn® DX 24mm faced and Donn DC 15mm faced exposed grid.
MetaPan P™ is ideal for commercial buildings, transportation and healthcare facilities that require a long life, easy clean robust accessible acoustical ceiling.
• For interior use only, and not in direct contact with water.
• Maximum humidity/temperature 95% R/H at 45°C.
• Back loading max. distributed load 1.0kg/m², point loads to be independently supported.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1(c)
Clause
B2.3.1 (c) (i): 5 years if building elements are easy to access and replace.
Asona MetaPan P ceiling tiles with
only normal maintenance will have a minimum durability of at least 5 years when
installed in accordance with; manufacturer’s installation requirements and
AS/NZS 2785:2020.
use
history. No test methods available.
- Clause C3 Fire affecting areas beyond the fire source: Performance C3.4(a)
Clause C/AS2 3.4(a):
Asona MetaPan has a Fire Material
Group Number 1-S (ISO A1) by MBIE Building Performance Surface Finishes
Standards Comparison 2938, 01 March 2015 in accordance with EN 13501-1:2007.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
B2 Durability and C3 Early Reaction to Fire