Technical Statement
Product Description
Triton Sport 40™ is high impact resistant glass fibre acoustical ceiling & wall panel with reinforced woven glass fabric facing. The panel is designed to provide high sound absorption in areas subject to impact, knocks and bumps.
Manufactured from woven faced Sonatex™ composite facer panel laminated to a 80 kg/m³ bio-soluble glass fibre absorber. DX24 suspension grid from galvanised steel.
Impact resistant construction, resists damage from bumps and knocks. Chip, crack and puncture resistant facing. Proprietary wide faced T38 suspension grid system with CL104 brackets secure the system against ball impact.
Can be made in a range of sizes, max width 1000 mm, length to 3000mm
Scope of use
Acoustic ceiling and wall panel for use with proprietary suspension grid system suitable for fire exit way and all other sprinklered & non sprinklered buildings.
High sound absorption, ideal for large volume spaces. NRC 0.95 for control of reverberation.
Triton Sports 40™ panel is ideal for use in classrooms, gymnasiums, halls, and corridors to control reverberation and background noise levels.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1, B2.3.2
- Clause C3 Fire affecting areas beyond the fire source: Performance C3.4
- Clause F2 Hazardous building materials: Performance F2.3.1
Notes
B2.3.1(c) - 5 years
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
NZBC verification test C/VM2, Cone Calorimeter Test.
Branz Fire Test report FH5020 - available upon request
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
Triton 40 Sport™ is ideal for use in classrooms, gymnasiums, halls, corridors etc to control reverberation and background noise levels.
Installation requirements
Shall not commence until the building is water tight and dry. Light fittings shall be independently supported, use CLW95 hold down brackets to secure panels against uplift from ball impact. It is recommended that air grilles be installed in the ceiling to balance air pressure differentials. Do not use in ceilings with negative air return plenums.
Minimum installation standard to AS/NZS 2785 and ASTM C636. Installation to be only by the manufacturer’s accredited installer, using the manufacturer’s technical services. Accredited installers to be members of the Association of Wall and Ceiling Industries of New Zealand (AWCI)
Maintenance requirements
Clean with vacuum or soft brush. Re-surfacing of soiled panels available, consult Asona.
Environmental
Made from 80% recycled local content, low embodied energy, product and packaging can be recycled in NZ. Low VOC <0.002 Mg/M²/hr per ASTM D5116. Renew & recycle service available to extend product life and reduce construction waste.
Quality Assurance
 |
ISO 9001 (Quality Management) |
Relationships
 |
Member of New Zealand Green Building Council |
 |
New Zealand Made |
|
AWCI (Association of Wall & Ceiling Industries) |