Scope of use
The Viking WarmSpan System is designed for use as an insulating roof on buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and maximum floor plan areas; and,
- on limited access flat roofs with steel structural decks subject to specific structural design; and,
- with roofs constructed to drain water to gutters and drainage outlets complying with the NZBC; and,
- with roofs constructed to suitable falls (refer paragraph 15.3 and 15.4 of the Warm Roof BRANZ Appraisal); and,
- with no integral roof gardens; and,
- situated in NZS 3604 Building Wind Zones, up to, and including Extra High.
The Viking WarmSpan System has also been appraised for duability and thermal performance as an insulated roofing system on buildings that are the subject of specific design with no building height restriction. Building designers are responsible for the building design and for the incorporation of the Viking WarmSpan System into their design in accordance with the declared properties and instructions of Viking Roofspec.
The Viking WarmSpan System must be installed by Viking Roofspec Licensed and Trained installers.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.1
- Clause B2 Durability: Performance B2.3.1, B2.3.1(b)
- Clause E2 External moisture: Performance E2.3.1, E2.3.2
- Clause F2 Hazardous building materials: Performance F2.3.1
- Clause H1 Energy efficiency : Performance H1.3.1, H1.3.1(a)
Installation requirements
Installation shall be carried out by a Viking Roofspec trained and licensed installer. Installation shall be undertaken in accordance with all relevant technical information related to the selected installation method, including information contained within the appraisal. Long term properties of the material may be affected by contact with petroleum-based products such as oils, greases and solvents.
Maintenance requirements
The membrane roof system must be regularly checked (at least annually) for damage, rubbish and debris. Damage, such as small punctures and tears must be repaired and coatings reapplied as recommended by Viking Roofspec Ltd. Special care must be taken when inspecting the membrane roof systems to ensure the continuing prevention of moisture ingress, and repairs must be undertaken when required. Drainage outlets must be maintained to operate effectively.
Warrantees
The Viking WarmSpan System is backed by a 20-year product warranty. For specific projects, Viking WarmSpan can be eligible to be covered by Viking's Full System Warranty, which covers the product and installation in one document (conditions apply).