Technical Statement
Product Description
True Board and Batten style cladding. Go with traditional or a more modern take using a variety of board and batten widths and depths.
Use suitable timbers from the Hermpac range to achieve your design intent. Stain, oil or paint options available.
A resurgence in recent years has seen this very robust cladding option re-appear with a modern take.
Scope of use
The Hermpac Board and Batten Weatherboard Cavity System has been appraised as an external, vertically fixed wall cladding system within the following scope:
- the scope limitations of NZBC Acceptable System E2/AS1, Paragraph 1.1; and,
- constructed with timber framing complying with the NZBC; and,
- with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/AS1, Table 2; and
- situated in NZS3604 Wind Zones up to, and including Extra High.
For weathertightness and
structural wind loading for buildings within the following scope:
-
the scope limitations of NZBC
Acceptable Solution E2/ AS1, Paragraph 1.1 with regards to building
height and floor plan area; and,
- constructed with timber framing
complying with the NZBC;
and,
- situated
in specific design wind pressures up to a maximum design differential ultimate
limit state (ULS) of 2.5 kPa.
Refer BRANZ Appraisal No. 828 (2020)
Or refer Hermpac website for direct fix options (risk score 0-12).
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.1, B1.3.2, B1.3.3, B1.3.3(a), B1.3.3(h), B1.3.3(j), B1.3.3(q), B1.3.4
Hermpac Board & Batten Cladding System meets Clause B1 Structure: B1.3.1, B1.3.2, B1.3.4 and B1.3.3 (a) (h) (j) and (q)
- Clause B2 Durability: Performance B2.3.1(b), B2.3.2
Hermpac Board & Batten Cladding System meets Clause B2 Durability: B2.3.1 (b) 15 years and B2.3.2.
- Clause E2 External moisture: Performance E2.3.2
Hermpac Board & Batten Cladding System meets Clause E2 External Moisture: E2.3.2
- Clause F2 Hazardous building materials: Performance F2.3.1
Hermpac Board & Batten Cladding System meets Clause F2 Hazardous Building Materials: F2.3.1
Notes
The Hermpac Board and Batten Weatherboard Cavity System is an Alternative Solution in terms of NZBC compliance.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
The Hermpac Board and Batten Weatherboard Cavity System was tested in accordance with, and meets the requirements of E2/VM1.
This cladding system can be direct fixed with a risk score of 0-12, or fixed over a cavity (18/20 or 40/45mm) with a risk score of 0-20.
Refer Hermpac Product Technical Statement.
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Use in Service History
Board and Batten has been used in New Zealand for a very long time. True Board and Batten is a very robust and proven cladding.
Hermpac Board and Batten can be installed over an 18/20mm cavity or 40/45mm cavity. The 40-45mm cavity offers a structurally fixed option.
For 18mm Western Red Cedar cavity batten options refer BRANZ Appraisal 1189 (2021).
Product Criteria
Design requirements
The Hermpac Board and Batten Cavity System is designed to be used as an external cladding, fixed vertically on flat surfaces. The profiles are manufactured in accordance with NZS 3617 and BRANZ Bulletin 411.
There is a range of standard and custom profile designs with a focus on innovation and product development. Refer to www.hermpac.co.nz for latest profiles.
Refer Product Technical Statement for Scope of Use.
Installation requirements
The system must be installed in accordance with the Hermpac Board and Batten Cavity System Installation Specification, BRANZ Appraisal 828 (2020), Hermpac Board and Batten construction drawing details (ref: HC-BBAT) and Product Installation Checklist.
For direct fix refer Hermpac Installation Specification Direct Fix and Hermpac Construction Drawings Direct Fix.
Please refer https://www.hermpac.co.nz/architect-dowloads for technical literature or email technical@hermpac.co.nz
Maintenance requirements
Maintenance of the Hermpac Board and Batten Cavity System is the building owner's responsibility.
Annual inspections must be made to ensure that all aspects of the cladding system, including flashings, remain in a weatherproof condition. Any damaged areas or areas showing signs of deterioration which would allow water ingress, must be repaired immediately. Sealant, coatings, flashings or the weatherboards must be repaired in accordance with the relevant manufacturer's instructions.
Maintenance requirements will depend on the coating type that is applied. Please refer to the coating manufacturer's specification. Specific maintenance schedules for re-coating oil stains are issued on a project specific basis.
Regular cleaning (at least annually) of the surface finish with water and a mild detergent is recommended to remove grime, dirt and organic growth, to maximise the life and appearance of the cladding.
Warrantees
Refer Hermpac Board & Batten Product Technical Statement.
Environmental
Hermpac timbers are available via a number of independent third party sustainability certification schemes including FSC, PEFC, SDI, and CSA.
Hermpac timbers meet the requirements of clause F2 Hazardous building materials F2.3.1 and does not present a health hazard to people.
Hermpac holds the Declare label for Western Red Cedar, Yellow Cedar and Kanda.
Relationships
|
New Zealand Made |
|
FSC
SGS-COC-008082 |
|
PEFC
SGS-PEFC/COC-1212 |
Building Product Information Requirements
Manufacturer
Legal Trading Name:
Hermpac
Business Email:
technical@hermpac.co.nz
Contact Number/s:
09 4219840
Product Identifier
CLASS 2
Warnings
This product has no warnings associated with it.