Compliance Statement
Scope of Use
The 650C system must be used within the limitations specified by Inpro for the particular product configuration.
- The nominal structural joint width must be confirmed against the approved construction documentation and Inpro product data before manufacture or installation.
- The surrounding substrate must be structurally adequate to support the expansion joint system and its fixings.
- The system must be installed onto a level and suitable substrate in accordance with Inpro's installation requirements.
- The 650C architectural joint cover does not determine the required structural seismic gap. Structural joint width and movement requirements remain the responsibility of the project structural designer.
- The required movement range must be established by the project structural engineer or other suitably qualified project designer.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.3(f)
https://inprocorporation2019.my.salesforce.com/sfc/p/#6g000001VB0l/a/UK000002PIlD/d9cTzJ1xQrqobC8HXZxxZBlNCQqQoUJbfTKmrmJM5jE
https://www.inprocorp.com/products/650-series-6-152mm-12-j650c-a07-150-exterior-expansion-joints
- Clause B2 Durability: Performance B2.3.1(c)
https://inprocorporation2019.my.salesforce.com/sfc/p/#6g000001VB0l/a/UK000002LDCS/paDi0VbfI3_QM8gYxhd8OaorYfzxZRJjN8rcE7qUT_Q
https://www.inprocorp.com/products/650-series-6-152mm-12-j650c-a07-150-exterior-expansion-joints
- Clause E2 External moisture: Performance E2.3.2
https://inprocorporation2019.my.salesforce.com/sfc/p/#6g000001VB0l/a/UK000002PJoK/xmD1XcEqyQMbU2cqRGZxB842M5CiIDI5QhnYuWq5jQs
https://inprocorporation2019.my.salesforce.com/sfc/p/#6g000001VB0l/a/UK000003Femz/4TZoaI032aM3k3SuV6xvQO.rUKFi2ZjizBYa65.u3.I
Notes
B1 Structure: The 650C Series is designed to accommodate structural expansion-joint movement resulting from conditions including Earthquake movement, Thermal expansion and contraction, Wind-induced building movement, Lateral/shear movement.
B2 Durability: The 650C system incorporates materials designed for exterior use, including aluminium, stainless-steel fixings and weather-resistant composite exterior panels.The composite metal exterior panel incorporates an architectural-grade fluoropolymer coating meeting AAMA 2605 requirements. Periodic inspection and maintenance of waterproofing interfaces, sealants, cover assemblies is required to ensure continued performance.
E2 External Moisture: The 650C Exterior Wall Expansion Joint contributes to the external moisture management of the building envelope by providing a weather-resistant expansion joint cover and accommodating compatible waterproofing membranes. JM650C is not, by itself, a complete roofing or cladding system.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
Inpro JointMaster® 650C Exterior Coverplate Series technical data
Inpro 650C-A07 Wall-to-Wall details
Inpro 650C-A09 Wall-to-Corner details
Inpro 650C-A07/A09 Installation Instructions
Inpro 650C-A07/A09 PDF, CAD and BIM/Revit Models.
Inpro reinforced moisture/vapour barrier technical information
Inpro reinforced moisture/vapour barrier installation instructions
Inpro JointMaster warranty information