Technical Statement
Product Description
VSS solar powered opening skylights are available in 8 sizes. Suitable
for installation within the range from 15º to 90º. VSS skylight is top
hinged and consists of the following integrated components – an interior
condensation drainage gasket, pre-finished white wooden frame and sash, for all
sizes fitted with proprietary VELUX motor, exterior maintenance-free aluminium
cladding/counter flashing, ASA corner keys, and an insulating thermal pane.
Insulating glass unit constructed of a stainless steel spacer with "warm edge"
technology, with glazing of internal laminated glass, Argon
filled cavity, low E3 coating applied to underside of external toughened
glass pane. Fitted with proprietary VELUX
motor, comes with external mounted solar panel with integrated rain sensor and
wall mounted, battery operated keypad.
Scope of use
Suitable for all roofs with a pitch between 15-90 degrees, used in conjunction with VELUX proprietary flashings or custom-made flashings in accordance with the latest version of the New Zealand Roofing Code of practice.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1, B2.3.2
Product is CodeMark certified. (BRANZ CM-1008)
- Clause E2 External moisture: Performance E2.3.1, E2.3.2
Product is CodeMark certified. (BRANZ CM-1008)
- Clause F2 Hazardous building materials: Performance F2.3.1
Product is CodeMark certified. (BRANZ CM-1008)
- Clause G4 Ventilation: Performance G4.3.1
Product is CodeMark certified. (BRANZ CM-1008)
- Clause G7 Natural light: Performance G7.3.1, G7.3.2
Product is CodeMark certified. (BRANZ CM-1008)
- Clause H1 Energy efficiency : Performance H1.3.1, H1.3.2E
Product is CodeMark certified. (BRANZ CM-1008)
Notes
Complies to AS/NZS 2208 Safety glazing materials in buildings - glass is stamped with compliance to the Standard and labelling on the skylight frame.
Complies to NZS 4223.4 Code of practice for glazing in buildings - Wind, dead, snow and live actions. Tested in an independent facility overseas.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
B2/AS1 Durability - AS 4285 - VELUX Skylights satisfy
the durability requirements specified for Non-structural Roof Cladding elements
and External Window/Door Joinery.
C3 Protection from Fire - AS 1530 - VELUX Skylights have
been classified as “non-combustible” according to AS 1530 test methods.
E2 External Moisture - AS 4285 - VELUX Skylights have
passed tests for weather tightness, concentrated load, non-cyclonic and
cyclonic wind pressures according to Australian Skylight Standard AS4285 test
methods.
F2 Hazardous Building Materials - NZS 4233: Part 4, AS/NZS 4666
- VELUX Skylights comply with requirements for sloped Insulating Glass Units.
G4/AS1 Natural Ventilation (1.2, 2.1) - VELUX Opening Skylights can be used to
meet the
G4 Natural Ventilation requirements.
G7 Natural Light - VELUX Skylights can be used to meet the
G7
Natural Light requirements.
H1 Energy Efficiency - NZS 4218 - VELUX Skylights exceed the
minimum R-value requirements for skylights in all climate zones.
Evidence: 30+ years of historical use in New Zealand
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Use in Service History
40+ years in New Zealand
Product Criteria
Design requirements
VSS skylights are modular solar powered venting skylight intended
for roof pitches between 15 and 90 degrees. They are available in standard sizes
only. The IGU glazing unit has argon gas fill and Low E3 applied to the inside
surface of the outer pane. The IGU unit meets the requirements of NZBC F2.
VSS skylights are fitted with insect screen
VSS skylights have been tested for impact but are not intended
to be part of a trafficable roof surface.
VSS skylights do not have a fire rating.
Installation requirements
Install VSS solar powered skylight in accordance
with instructions supplied with VSS solar powered skylight and local building code
requirements. 454443-2019-01 VS AUS_KOR.indd (azureedge.net) Align
skylight with the trim opening, free of warp or twist, maintaining dimensional
tolerances. Attach skylight to the trim-out frame with screws furnished by
manufacturer. Coordinate attachment and seal of perimeter air and vapor barrier
material. Weathertightness to be achieved by using either VELUX proprietary
flashings installed in accordance with supplied installation instructions, or
custom-made flashings made in accordance with the latest version of NZ Roofing
Code of Practice.
When roof pitch exceeds 30 degrees the solar panel must be fitted at the head of the skylight. (Extension cable is included in skylight box)
Maintenance requirements
For maintenance requirements refer to http://https//www.velux.co.nz/service-and-warranty/maintenance.
Exterior surfaces must be cleaned with clean water at least once
a year, subject to the environmental conditions present.