Double SRP™ Stud walls are generally used where two way FRR [Fire Resistance Rating] or superior acoustic performance is required. This is mainly in inter-tenancy walls and corridors.
Walls are installed as two separate parallel frames with a specified gap between them, using the relevant GIB® documentation in order to achieve the required STC and FRR rating. Refer to GIB® Noise Control Systems September 2017 and GIB® Fire Rated Systems October 2018 for more information.
Our steel walls are fast and simple to install, lightweight, strong, durable, precise, dimensionally stable, pest/ rot or fungus resistant, and made from recyclable raw material.
Designed to, and manufactured from, a compliant base material, to the relevant New Zealand/ International Standards and to the relevant parts of the New Zealand Building Code.
Contact us to review your specification.
Double SRP™ Stud walls are generally used where two-way FRR [Fire Resistance Rating] or superior acoustic performance is required. This is mainly in inter-tenancy walls and corridors.
Internal non load-bearing partitions - please refer to SRP Wall System Heights Tables (SRP Wall Systems Handbook)
B1/ VM1An Engineered design is required - this needs to be done by a suitably qualified Engineer, who can also provide a PS-1.
SRP uses GALVSTEEL® manufactured by New Zealand Steel. The continuous hot-dip galvanized Zinc coating conforms to the industry standard required for this application; Z275 (275 g/m2 total). New Zealand Steel made GALVSTEEL® for framing is backed by a 50-year Durability Statement to demonstrate compliance with NZBC Clause B2-Durability, when used and maintained as referred to in the current New Zealand Steel’s Durability Statement.
G6/ AS1
1. ASNZ4600 (Steel chemical composition, gauge grade tolerance, galvanised coating, testing statistics,yield pint etc.
2. NZS4129 (seismic)
3. NZS3404 (fabrication)
4. AS1397 (sheet and strip)
5. AS1538 (cold formed structures)
6. ASZNZ1170 (steel structures)
7. AS/NZS2785 (Suspended Ceilings)
Please contact Steel Rollformed Products Ltd - for Design Assistance, or visit www.srpltd.co.nz
An Engineered design is often required - this needs to be done by a suitably qualified Engineer, who can also provide a PS-1.
Please refer SRP Wall Systems Handbook for installation requirements.
No maintenance required - SRP Galv Steel products/ systems are typically concealed/ hidden (Within walls/ ceilings), once installed.
PRODUCT CODES: DOUBLE SRP™ STUD WALL
This product has no warnings associated with it.