Technical Statement
Product Description
Scope of use
For use on roof pitches 0-60 degrees. (It is recommended for roof pitches below 5 degrees for the skylight to be pitched to 5 degrees minimum to ensure an improved water runoff and to limited ponding on the glass)
FCM skylights are not fire rated but can be used under New Zealand Building Code C/AS2 Part 5 in Risk Group SH buildings.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1, B2.3.1(b), B2.3.2
CodeMark Certified (BRANZ CM-1008)
- Clause E2 External moisture: Performance E2.3.1, E2.3.2, E2.3.7
CodeMark Certified (BRANZ CM-1008)
- Clause F2 Hazardous building materials: Performance F2.3.2, F2.3.3
CodeMark Certified (BRANZ CM-1008)
- Clause F4 Safety from falling: Performance F4.3.1
CodeMark Certified (BRANZ CM-1008)
- Clause G4 Ventilation: Performance G4.3.1, G4.3.3
CodeMark Certified (BRANZ CM-1008)
- Clause G7 Natural light: Performance G7.3.1, G7.3.2
CodeMark Certified (BRANZ CM-1008)
- Clause H1 Energy efficiency : Performance H1.3.1, H1.3.2E, H1.3.3, H1.3.3(f)
CodeMark Certified (BRANZ CM-1008)
Notes
B2.3.1(b) - 15 years, 10 year warranty on all VELUX skylights
Product Technical Statement
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
-
B2/AS1 Durability - AS 4285 - VELUX Skylights satisfy the durability requirements specified for Non-structural Roof Cladding elements and External Window/Door Joinery.
VELUX Skylights have passed tests for weather tightness, concentrated load, non-cyclonic and cyclonic wind pressures according to Australian Skylight Standard AS4285 test methods.
- C3 Protection from Fire - AS 1530 - VELUX Skylights have been classified as “non-combustible” according to AS 1530 test methods.
- E2 External Moisture - AS 4285 - VELUX Skylights have passed tests for weather tightness, concentrated load, non-cyclonic and cyclonic wind pressures according to Australian Skylight Standard AS4285 test methods.
- F2 Hazardous Building Materials - NZS 4233: Part 4, AS/NZS 4666 - VELUX Skylights comply with requirements for sloped Insulating Glass Units.
- G4/AS1 Natural Ventilation (1.2, 2.1) - VELUX Opening Skylights can be used to meet the G4 Natural Ventilation requirements.
- G7 Natural Light - VELUX Skylights can be used to meet the G7 Natural Light requirements.
- H1 Energy Efficiency - NZS 4218 - VELUX Skylights exceed the minimum R-value requirements for skylights in all climate zones.
-
Evidence: 30+ years of historical use in New Zealand
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
FCM skylights are modular fixed, non-venting skylight intended for roof pitches between 0 and 60 degrees. They are available in standard sizes only. The IGU glazing unit has argon gas fill and Low E3 applied to the inside surface of the outer pane. The IGU unit meets the requirements of NZBC F2
FCM skylights have been tested for impact but are not intended to be part of a trafficable roof surface.
FCM skylights do not have a fire rating.
When using proprietary VELUX blinds in conjunction with the FCM skylight, a ZZZ 199 accessory tray needs to be purchased installed before the blind can be fitted.
Installation requirements
Install FCM skylight in accordance with manufacturer’s installation instructions, supplied with FCM, and with local building code requirements.
Align skylight with curb, free of warp or twist, maintaining dimensional tolerances. Attach skylight to curb with screws furnished by manufacturer. Coordinate attachment and seal of perimeter air and vapor barrier material. Provide insulation of the curb for maximum energy efficiency. Install site made flashing in accordance with latest version of New Zealand Roofing Code of Practice to achieve weather- tight installation.
Maintenance requirements
For maintenance requirements refer to http://https//www.velux.co.nz/service-and-warranty/maintenance.
Exterior surfaces must be cleaned with clean water at least once a year, subject to the environmental conditions present.
|
Date last validated:
03 November 2023 |
|
Date last updated:
03 November 2023 |