Compliance Statement
Scope of Use
Refer to http://www.mulfordplastics.co.nz/products/panelux/
The PaneLux® A1 Solid Aluminium Cladding System must be specified, installed, and maintained in accordance with the following documents, collectively referred to as the applicable PaneLux ®A1 Solid Aluminium Cladding System Technical Literature:
PaneLux® A1- Design Guide - PaneLux® A1 - Specification Guide and PaneLux® MasterSpec - PaneLux® A1 - LAB Extrusion System Installation Manual - PaneLux® A1 - SED -Specific Engineered Design - Installation Recommendations. PaneLux® A1 Visual & Quality Inspection Guide (for panel) - PaneLux® A1 - Processing and Technical Data Manual - PaneLux® A1 Cleaning and Maintenance Guide.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.1, B1.3.2, B1.3.3, B1.3.3(a), B1.3.3(h)
The PaneLux® A1 Solid Aluminium Cladding System tested in accordance with AS/NZS4284:2008 “Testing of Building Facades” with a SLS 2.5kPa with a ULS of 3.7kPa – refer Facadelab test report 23-02 dated 24th July 2023. www.mulford.co.nz
PaneLux® A1 panel technical properties – Yield Strength 122Mpa – Tensile Strength 146Mpa – Feiteng -Product Data Sheet. - Clause B2 Durability: Performance B2.3.1(b)
When installed and maintained in accordance with the specifications and instructions outlined in the PaneLux® A1Cleaning & Maintenance Guide (version V1-052024), the PaneLux® A1 Solid Aluminium Cladding System is expected to have a serviceable life exceeding 15 years. www.mulford.co.nz - Clause C3 Fire affecting areas beyond the fire source: Performance C3.4, C3.4(a), C3.7, C3.7(a)
PaneLux® material tested in accordance with EN13501-1:2007 (ISO9705-1:2016) and classified as Class A1- refer SGS Test Report AJFS2007005644FF dated 31st July 2020.
PaneLux® A1 material tested in accordance with ISO5660-1:2002 (Satisfying NZBC C/AS2 Appendix C C7.1 Type A & B)-refer BRANZ Test Report FH13948-001 Issue 1 dated 8th July 2021. www.mulford.co.nz - Clause E2 External moisture: Performance E2.3.2, E2.3.5, E2.3.7
PaneLux® A1 panel fixed to the LAB Extrusion System tested in accordance with AS/NZS4285:2008 “Testing of Building Facades” – refer Facadelab test report 23-02 dated 24th July 2023. www.mulford.co.nz - Clause F2 Hazardous building materials: Performance F2.3.1
The aluminium substrate is inert, and the coating system is inert after drying.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
Clause B1 STRUCTURE: Performance B1.3.1, B1.3.2, B1.3.3(a, h) – Alternative Solution
Clause B2 DURABILITY: Performance B2.3.1(b) – Acceptable Solution - B2/AS1
Clause C3 FIRE AFFECTING AREAS BEYOND THE FIRE SOURCE - Performance C3.4(a), C3.7(a) Acceptable Solution - C/AS1 and C/AS2
Clause E2 EXTERNAL MOISTURE – Performance – E2.3.2, E2.3.5, E2.3.7 – Alternative Solution
Clause F2 HAZARDOUS BUILDING MATERIALS – F2.3.1 – Alternative Solution
Design requirements
In accordance with NZS 3604:2011 for timber-framed buildings; or• In accordance with NZS 3404:2009 Part 1 and the NASH Standard Part 2: May 2019 for light steel-framed buildings. Or by specific engineering design (SED) in accordance with B1/VM1 Amendment 21 (2 November 2023), prepared by a suitably qualified chartered professional engineer.
Inter-storey drained joints must be installed to limit continuous cavities to a maximum of two storeys or 7 metres in height, whichever is less, as required by NZBC Acceptable Solution E2/AS1.
The PaneLux® A1 Solid Aluminium Cladding System is suitable for use within the scope limitations defined in NZBC Acceptable Solution E2/AS1, Third Edition, Amendment 10 (dated 5 November 2020), Paragraph 1.1.
http://www.mulfordplastics.co.nz/products/panelux/
Installation requirements
The PaneLux® A1 Solid Aluminium Cladding System must be installed by a Mulford New Zealand approved building professional, in accordance with the relevant PaneLux® A1 technical literature or project specific design.
The installer must provide a signed declaration confirming that the product has been installed in accordance with the conditions specified in this PTS, for consideration in the issuance of the Code Compliance Certificate (CCC).
Inter-storey drained joints must be installed to limit continuous cavities to a maximum of two storeys or 7 metres in height, whichever is less, as required by NZBC Acceptable Solution E2/AS1.
The PaneLux® A1 Solid Aluminium Cladding System is suitable for use within the scope limitations defined in NZBC Acceptable Solution E2/AS1, Third Edition, Amendment 10 (dated 5 November 2020), Paragraph 1.1.
http://www.mulfordplastics.co.nz/products/panelux/
Manufacturer
Legal Trading Name:
Mulford New Zealand
Company Website:
www.mulford.co.nz
Contact Number/s:
+64 09 4424051 0800888842
Importer
Legal Trading Name:
Mulford New Zealand
Business Email:
ordersgle@mulford.co.nz
Company Website:
www.mulford.co.nz
Contact Number/s:
09 4424051 0800 888842
Product Identifier
HTTP://WWW.MULFORDPLASTICS.CO.NZ/PRODUCTS/PANELUX/
Warnings
This product has no warnings associated with it.
 |