Compliance Statement
                                                                                            
                                                                                            
                                                                                                Scope of Use
                                                                                                Designed as a Heavy Duty Architectural Entry Mat Solution for front/back doors, side doors, service entrances & wind lobbies.
Key Benefits
    - Prevent slipping and trip's
 
    - Reduce maintenance and cleaning
 
    - Improves appearance
 
Usage Areas (Entrance area):
    - Public buildings
 
    - Education
 
    - Healthcare
 
    - Travel Terminuses
 
    - Commercial Offices
 
    - Retail Stores
 
    - Shopping Centre's
 
    - Leisure / Sport
 
                                                                                             
                                                                                            
                                                                                            
                                                                                                New Zealand Building Code (NZBC)
                                                                                                The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
                                                                                                - Clause D1 Access routes: Performance  D1.3.1, D1.3.1(a), D1.3.1(b), D1.3.1(c), D1.3.2, D1.3.2(a), D1.3.2(c), D1.3.3(c)
D1.3.1:
    - (a) Safely and easily approach the main entrance of buildings from the apron or construction edge of a building
 
D1.3.1 Access routes shall enable people to:
D1.3.1 Access routes shall enable people to:
    -  (c) Move into spaces within buildings by such means as corridors, doors, stairs, ramps and lifts
 
D1.3.2 At least one access route shall have features to enable people with disabilities to:
    - (a) Approach the building from the street boundary or, where required to be provided, the building car park,
 
    - (b) Have access to the internal space served by the principal access, and
 
    - (c) Have access to and within those spaces where they may be expected to work or visit, or which contain facilities for personal hygiene as required by Clause G1 “Personal Hygiene”.
 
D1.3.2 At least one access route shall have features to enable people with disabilities to:
    -  (b) Have access to the internal space served by the principal access
 
D1.3.3 Access routes shall:
    - (d) Have adequate slip-resistant walking surfaces under all conditions of normal use,
 
 
                                                                                             
                                                                                            
                                                                                            
                                                                                            
                                                                                                Evidence
                                                                                                The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
                                                                                                Meets NZBC requirements and ISO 9239-1:2010 test
Performance
    - UV Stabilized - High Degree of UV Protection
 
    - Moisture Absorption - 0.006%.Will not rot or smell
 
Fire Ratings / AS 1530 Part 3: / AS/ISO 9239 Part 1:
    - Spread of Flame (Index 0-10) 0
 
    - Smoke Developed (Index 0-10) 4-tested 8 July 2002, CSIRO
 
    - Average Critical Radiant Flux: 7.4 kW/m2
 
    - Average Smoke Obscuration: 362% min-tested September 2004, CSIRO
 
Cleaning & Stain Resistant Fibre
    - Will not absorb any staining materials
 
Lifetime No Zip, No Fray
    - No zippering will occur for the serviceable life of the carpet