Technical Statement
Product Description
Scope of use
Thermaflash window flashing tape can be used as a flexible flashing system around window and door joinery openings on timber and steel framed buildings within the following scope:
- Installed into and around joinery openings over the wall underlay and exposed frame to cover both the face and edge of the opening as a secondary weather resistant barrier.
- Installed at joinery heads to seal flashing upstands to the wall underlay.
- To assist the overall weathertightness performance of window and door joinery installations.
- To be used in conjunction with air seals and joinery flashing systems. Installer must check for air seal product compatibility with Thermaflash.
- Situated in NZS3604 Wind Zones up to, and including, ‘Extra High’.
- Suitable for residential builds (E2/AS1 timber framed and E2/AS4 steel framed) and medium rise buildings (E2/VM2).
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1(a), B2.3.1(b)
Clause B2 DURABILITY: Performance B2.3.1 (b), 15 years and B2.3.2. Thermaflash Flashing Tape meets these requirements.
- Clause E2 External moisture: Performance E2.3.2
Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. Thermaflash Flashing Tape contributes to meeting this requirement.
- Clause F2 Hazardous building materials: Performance F2.3.1
Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Thermaflash Flashing Tape meets this requirement and will not present a health hazard to people.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
Thermaflash window flashing tape has been appraised by BRANZ as a flexible system for use around window and door joinery for buildings with the following scope:
- Constructed timber and steel framing in accordance with scope limitations of NZBC Acceptable Solution E2/AS1 and NASH Building Envelope Solutions, Paragraph 1.1.
- With a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/AS1 or NASH Building Envelope Solutions, Table 2.
- With wall cladding systems complying with NZBC Acceptable Solution E2/AS1 or NASH Building Envelope Solutions, or a valid BRANZ Appraisal that specifies a flexible flashing system.
- With flexible wall underlays compatible with the flashing tape and complying with the NZBC
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
|
BRANZ Appraisal
1122 |
|
|
Product Criteria
Installation requirements
Thermaflash Install Guide
Maintenance requirements
No regular maintenance required.
Quality Assurance
|
ISO 9001 (Quality Management) |
Relationships
|
Member of New Zealand Green Building Council |
|
Date last validated:
09 October 2023 |
|
Date last updated:
09 October 2023 |