Product Description
TRS 6
- High performance
roofing and cladding product.
- G550 grade steel with minimum 0.40mm BMT and maximum 0.55 BMT
- Provides greater resistance to
high wind events such as tornados and cyclones.
SPECIFICATION AT A GLANCE
GENERAL
Minimum Roof Pitch 4 Degree
Effective Cover 762mm
Max.
Unsupported Overhang Contact “The Roofing Store”
SPANS
End Span 0.40/0.55 BMT 1000mm/1300mm
Internal Span 0.40/0.55 BMT 1450mm/2000mm
ROOF FIXINGS
LOW / MEDIUM
WIND ZONE
Timber: class 4 12 x 65mm with neo washer and embossed washer
Steeltite: 12 x 65mm with neo washer and embossed washer
HIGH WIND ZONE
Timber: class 4 12 x 65mm with neo washer and embossed washer,
approved profile’s metal washer and EPDM washer
Steeltite: 12 x 65mm with neo washer and embossed washer, approved
profile’s metal washer and EPDM washer
WALL CLADDING FIXINGS
Cladding fixing on 20mm,
H 3.1 Treated Battens
12 Gauge class 4 screws with neo
washers, miss 2 pans, miss 3 pans
every second on ends
TRS 6https://www.theroofingstore.co.nz/steel-roofing-and-cladding-profile-specifications