Compliance Statement
Scope of Use
The EFAFLEX CR Series, (Clean Room) Solution Doors are designed for environments requiring strict contamination control, such as laboratories, healthcare facilities, pharmaceutical manufacturing, and cleanroom production. These high-speed doors are suitable for internal applications requiring airtight seals and environmental separation.The product supports secure access, containment of airborne particles, and operational reliability in clean environments. Engineered for compatibility with building automation systems, it ensures seamless operation and compliance with cleanroom standards. With customisable sizes and finishes, the doors can be tailored to specific project requirements while maintaining compliance with hygiene regulations.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
Notes
Other provisions of the building code met provided in specific PTS sections for the doors.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
EFAFLEX CR Series complies with NZBC clause F3.3 provisions as follows:
- F3.3(a): Compliance is supported by testing to ISO 14644 cleanroom standards and third-party certifications for secure access systems, demonstrating the product’s ability to restrict unauthorized access effectively.
- F3.3(b): Independent testing validates its high-seal performance, preventing hazardous substances or contaminants from entering controlled environments.
- F3.3(c): Pressure release systems are designed in accordance with ISO cleanroom guidelines to allow harmless release of substances while maintaining operational safety.
- F3.3(f): Materials used in construction are certified as impervious and hygienic, meeting GMP requirements for easily cleaned surface finishes in cleanroom applications.
Compliance is assured when installed and maintained as per supplier instructions, with supporting evidence drawn from recognized international standards and supplier documentation.
Design requirements
The product is designed for use in cleanroom environments requiring contamination control.
Key considerations:
- Applications: Laboratories, healthcare, and pharmaceutical production.
- Safety Compliance: Meets ISO 14644 and GMP standards for hygiene and containment.
- Performance: High-speed operation with airtight seals for environmental separation.
Integration: Compatible with interlocks and building automation systems.
- Customization: Sizes and finishes tailored to project needs.
Installation requirements
Efaflex CR Series doors should be installed by qualified technicians experienced in high-speed industrial doors. Installation involves securely mounting the frame, connecting and testing electrical components, and calibrating sensors. Adherence to manufacturer instructions, correct tool usage, and precise alignment are essential to prevent operational issues. Installation should take place in stable temperature and humidity conditions to avoid misalignment or material expansion. Ensuring proper calibration of sensors and components minimizes performance issues and maintains safety in temperature-sensitive applications.
Maintenance requirements
Preventative maintenance is suggested in accordance with Efaflex’s maintenance schedules to ensure durability and optimal performance. Recommended tasks include regular visual inspections, cleaning, and checks on wear-sensitive parts like seals and sensors. Adjustments to door tension and recalibration of automation features help prevent issues in high-use environments. Key components, such as springs, electrical connections, and safety edges, should be inspected periodically, with replacements as necessary to maintain longevity and functionality. Efaflex can recommend a qualified contractor to perform these tasks and keep detailed records to support NZBC Clause B2 compliance and ensure reliable door operation.
Manufacturer
Legal Trading Name:
EFAFLEX Tor- und Sicherheitssysteme GmbH & Co. KG
Contact Number/s:
0800 3323539
Importer
Legal Trading Name: