Compliance Statement
Scope of Use
Hallmark Cavity Sliders are
designed for, but is not limited to, use in projects within the following
scope:
- Housing and residential
apartment buildings, and their associated ancillary and outbuildings - interior
use.
- Commercial buildings, and
their associated ancillary and outbuildings - interior use
Hallmark Cavity Sliders may
be used in projects outside this scope if other parties such as architects or
specifiers establish appropriate design and installation requirements.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1(b)
Hallmark Cavity Sliders have a durability beyond 15 years when
correctly installed and maintained, based on historical in-market use. - Clause D1 Access routes: Performance D1.3.1(b), D1.3.1(c), D1.3.4(f)
Hallmark Cavity Sliders can be used
within as accessible route where design consideration is given to compliance to
NZBC D1/AS1, paragraph 7.0.
Doors to be installed with door handles
that meet the requirements of NZBC D1/AS1 clause 7.0.5. The selection of hardware to meet these
requirements is not the responsibility of Hallmark Group. - Clause F2 Hazardous building materials: Performance F2.3.2, F2.3.3
Hallmark Cavity Sliders
and Doors are manufactured using inert, nontoxic materials.
If required, Hallmark Door vision panel
glazing complies with NZS 4223.3.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
NZS4223.3: 2016 Code of practice for
glazing in buildings Part 3: Human impact safety requirements
Design requirements
- Hallmark Cavity Sliders are
for interior use.
- This product is not
suitable for use in saunas, steam rooms, smoke houses etc.
-
This product is not fire
rated.
- See www.hallmarkgroup.co.nz/fire-doors for Hallmark fire rated doors.
Hallmark Cavity Sliders are
designed for, but is not limited to, use in projects within the following
scope:
- Housing and residential
apartment buildings, and their associated ancillary and outbuildings - interior
use.
-
Commercial buildings, and
their associated ancillary and outbuildings - interior use
Hallmark Cavity Sliders may
be used in projects outside this scope if other parties such as architects or
specifiers establish appropriate design and installation requirements.
Installation requirements
- Inspect Cavity Slider
units and doors for freight damage and defects. Hallmark must be notified
within 4 days if damage has occurred.
- Cavity Slider units and doors
must be installed in dry buildings only. When installed in situations with
excessive air movement (i.e. buildings not at ‘lock up’ stage) warranty is
voided. Interior doors must not be installed within the direct air movement of
an air temperature controller.
- Warp exceeding 5mm is
considered a defect on doors up to 2400x910mm. Doors exceeding this size carry
no guarantee against warp. Hallmark accepts no responsibility for defective
doors when the moisture content of the timber exceeds 18%.
- Install the door in
accordance with the consented or design drawings. Ensure doors are installed
plumb, level, and in plane, within the tolerances set out in the MBIE Guide to
materials, tolerances, and workmanship in residential construction.
Maintenance requirements
- The track system – head
track and wheel carriage units - and other hardware should be checked annually
for proper operation and to ensure fixings remain tight.
-
Doors installed in
bathrooms or laundries that become scratched or damaged are to have the coating
repaired immediately. Any repair work must be carried out under the
instructions of the coating manufacturer.
Manufacturer
Legal Trading Name:
Hallmark Group
Business Email:
sales@hallmarkgroup.co.nz
Contact Number/s:
03 3134754 0800 486237
Product Identifier
SINGLE, NO CLOSING JAMB, BI-PARTING, DOUBLE STACKING, BI-PART DOUBLE STACKING, RIGHT ANGLE (CORNER MEETING)
Warnings
This product has no warnings associated with it.
 |
Date last validated:
10 June 2025 |
 |
Date last updated:
10 June 2025 |
|