Compliance Statement
                                                                                            
                                                                                            
                                                                                                Scope of Use
                                                                                                Kooltherm K7 Pitched Roof Board is a rigid thermoset phenolic insulation for roof/ceiling applications. It has a fibre-free core and a highly reflective aluminium foil on both sides autohesively bonded to the insulation core during manufacture. 
    - Suitable for timber and steel frame roof construction. 
 
    - Suitable for new build and refurbishment.
 
                                                                                             
                                                                                            
                                                                                            
                                                                                                New Zealand Building Code (NZBC)
                                                                                                The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
                                                                                                - Clause B1 Structure: Performance  B1.3.1, B1.3.2, B1.3.3(a), B1.3.4
Kooltherm K7 Pitched Roof Board meets the performance requirements of NZBC Clause B1 Structure (B1.3.1, B1.3.2, B1.3.3(a), B1.3.4)
 - Clause B2 Durability: Performance  B2.3.1(a)
Kooltherm K7 Pitched Roof Board meets the performance requirements of NZBC Clauses B2 Durability (B2.3.1 (a) 50 years
 - Clause E3 Internal moisture: Performance  E3.3.1
Kooltherm K7 Pitched Roof Board meets the performance requirements of NZBC Clause E3 Internal Moisture (contributes to E3.3.1)
 - Clause F2 Hazardous building materials: Performance  F2.3.1
Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Kingspan Kooltherm K7 meets this requirement and will not present a health hazard to people.
 - Clause H1 Energy efficiency : Performance  H1.3.1, H1.3.2E
Clause H1 Energy Efficiency (contributes to H1.3.1 and H1.3.2E) by testing and comparison with acceptable solutions H1/AS1 and H1/AS2 and verification methods H1/VM1 and H1/VM2
 
                                                                                             
                                                                                            
                                                                                                Notes
                                                                                                Kooltherm K7 Pitched Roof Board is manufactured to the highest standards and certified under the following management systems:
    - ISO 9001:2015 Quality Management
 
    - ISO 14001:2015 Environmental Management
 
    - ISO 45001:2018 Health and Safety Management
 
    - ISO 50001:2018 Energy Management
 
Product Testing:
    - Compressive Stress AS 2498.3: Typically exceeds 100 kPa at 10% compression
 
    - Water Vapour Resistance AS 2498.5-1993 Method 5: > 35 MN.s/g
 
Fire Performance:
    - Ignitability, Flame Spread, Heat Release, Smoke Release AS 1530.3: Spread of Flame Index: 0, Smoke Development ≤ 3
 
    - Flame Propagation (AS 1366) AS 2122.1: Complies
     
                                                                                             
                                                                                            
                                                                                            
                                                                                                Evidence
                                                                                                The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
                                                                                                Kooltherm K7 Pitched Roof Board meets the performance requirements of NZBC Clause B1 Structure (B1.3.1, B1.3.2, B1.3.3(a), B1.3.4), Clauses B2 Durability (B2.3.1 (a) 50 years, Clause E3 Internal Moisture (contributes to E3.3.1 ), Clause F2 Hazardous Building Materials (F2.3.1), and Clause H1 Energy Efficiency (contributes to H1.3.1 and H1.3.2E) by testing and comparison with acceptable solutions H1/AS1 and H1/AS2 and verification methods H1/VM1 and H1/VM2 providing: 
    - It is not damaged, dented or fractured. 
 
    - It is installed in accordance with installation instructions. 
 
    - It is installed by or under guidance of Licensed Building Practitioners.