Level of assurance needed to demonstrate NZ Building Code Compliance
Supporting documentation should include technical information by manufacturer and either a BRANZ or independent Appraisal or CodeMark
|
|
Pro Clima
confirms that this minimum level of assurance has been met or exceeded by the following:
BRANZ Appraisal 989
|
Technical Statement
Product Description
Scope of use
- SOLITEX EXTASANA ADHERO
®
has been appraised for use as a wall underlay over fibre cement, oriented strand board and plywood rigid wall underlays, on timber and steel framed buildings
- SOLITEX EXTASANA ADHERO
®
has been appraised for use as a roof underlay over OSB and plywood roof sarking, on timber and steel framed buildings
- SOLITEX EXTASANA ADHERO
®
has been appraised for use as a roof and wall underlay on CLT and SIP constructions
- The above scope is within the limitations of NZBC E2/AS1, and situated with NZS 3604 wind zones up to and including 'Extra High'
- For more information on its scope of use, refer to the BRANZ Appraisal
- SOLITEX EXTASANA ADHERO
®
has also been appraised for use over rigid wall underlays or roof sarking on buildings subject to specific weather-tightness design, that fall outside of the scope of NZS3604 and E2/AS1. In these cases, building designers are responsible for the building design and the incorporation of ADHERO
®
self adhesive underlay in to their design, in accordance with its declared properties and the instructions of Pro Clima NZ Ltd
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
Notes
SOLITEX EXTASANA ADHERO
®
, if used, designed, installed and maintained in accordance with the statements and conditions of the Installation Guide and BRANZ Appraisal, will meet, or contribute to meeting the following provisions of the NZBC:
- Clause B2 DURABILITY: Performance B2.3.1(a), not less than 50 years, B2.3.1(b), 15 years and B2.3.2. SOLITEX EXTASANA ADHERO
®
Underlay meets these requirements.
- Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. When used as part of the roof or wall cladding system, SOLITEX EXTASANA ADHERO
®
Self-Adhesive Underlay will contribute to meeting this requirement.
- Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. SOLITEX EXTASANA ADHERO
®
Self-Adhesive underlay meets this requirement and will not present a health hazard to people.
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
|
BRANZ Appraisal
989 |
|
|
Use in Service History
Used in:
- Von Haast Building, Canterbury University
- Parklane Retirement Village, Christchurch
- Hilton Hotel Auckland refurbishment
- Housing New Zealand CLT project, Northcote, Auckland
- Goodman Commercial units, Highbrook, Auckland
- Aotea College, Wellington
- Massey University campus, Albany, Auckland
- Alexandra park Apartments, Greenlane, Auckland
- Great King St, Dunedin development
- St Pauls Apartments reclad, Wellington
- Latitude Residences, Tauranga
- Housing for Elderly project, Wadier Place, Henderson
- Waitara High School, Taranaki
- Victoria Villas, Wellington
- NZSIP panel houses - various locations across NZ
- Formance SIP panel houses - various locations across NZ
- Westlight Apartments, Glen Eden
- Auckland City Mission, Hobson St
Product Criteria
Design requirements
- ADHERO
®
must not be exposed to the weather or UV light for a total of more than 180 days before being covered by the wall or roof cladding.
- When ADHERO
®
is used in conjunction with LOSP treated timber, the solvent from the timber treatment must be allowed to evaporate (approx 1 week) prior to the installation of the underlay.
- ADHERO
®
may be used as a flexible wall underlay over plywood or fibre cement as specified in NZBC E2/AS1 paragraph 9.1.7.1.
- When ADHERO
®
is used over a rigid wall underlay of (FC or Plywood), it may be used as a temporary weather protecting sheathing to allow the internal lining of framed buildings to proceed before the wall cladding is installed.
- Timber and steel framing must be provided in accordance with the requirements of the NZBC and the rigid underlay and cladding supplier
- CLT and SIP constructions that ADHERO
®
is to be used over must meet the requirements of the NZBC
- Refer to BRANZ Appraisal 989 for more detailed design information
Installation requirements
1. Installation shall always be carried out as follows:
- By an LBP, or under the supervision of an LBP with the relevant Licence class
- To comply with all of the relevant technical information, including the
SOLITEX EXTASANA ADHERO
®
Installation Guide, Installer Checklist and BRANZ Appraisal 989
- On framed walls, the product must cover the full extent of the substrate it is adhering to
- On CLT and SIP constructions, the product must be installed as directed by the CLT or SIP system proprietor, and as required by the NZBC Clause E2
- Markings should be made on the substrate before the first piece of ADHERO
®
is installed, so the product is installed level or plumb
- care should be taken to avoid wrinkles or folds in the product
- 150mm laps in all directions
- The product should be smoothed with a 150mm wide roller or the PRESSFIX XL tool to ensure adhesion to the substrate
- Refer to BRANZ Appraisal 989 and the ADHERO
®
installation guide for more detailed installation information
Maintenance requirements
Provided it is not exposed to the weather or ultra-violet light for a total of more than 180 days, and provided the exterior cladding is maintained in accordance with the cladding manufacturer’s instructions and the cladding remains weather resistant, SOLITEX EXTASANA ADHERO
®
underlay is expected to have a serviceable life equal to that of the cladding. No maintenance is required during this time
Warrantees
The Pro Clima Warranty Agreement applies to SOLITEX EXTASANA ADHERO
®
as per other Pro Clima products used in the construction.
The Warranty period for products shall begin at the time of the sale of the product to the first customer by Pro Clima NZ Ltd, and shall end six years after this time. The warranty period shall extend to ten years after the time of the sale of the product to the first customer by Pro Clima NZ Ltd if installation of the products is carried out solely in combination with Pro Clima standard products, insofar as products for the relevant application are available as part of the Pro Clima system.
Please contact Pro Clima NZ on 0800 PROCLIMA or welcome@proclima.co.nz for more information on the terms and conditions of the Warranty
Relationships
|
Member of New Zealand Green Building Council |
|
International Living Future Institute
PRC-0007 |
|
Date last validated:
07 November 2023 |
|
Date last updated:
07 November 2023 |
Disclaimer
The Product Technical Statement (PTS) template is copyright to Construction Information Limited. However the content of this PTS is the responsibility of the product manufacturer/supplier.
Refer to the miproducts Terms and Conditions
|
|
|