Product Description
TRS 5
-Designed for residential and commercial roofing and wall cladding.
-Comes in G550 grade steel with minimum 0.40mm BMT and maximum 0.55 BMT.
-Profile with 0.55 BMT gives greater resistance to high wind events such as tornados and cyclones.
GENERAL
Minimum Roof Pitch- 3 Degrees
Effective Cover- 765mmMax.
End Span- 0.40/0.55 BMT1100mm/1500mm
SPANS
Internal Span 0.40/0.55 BMT 1600mm/2200mm
For Unsupported Overhang, please contact - The Roofing Store
ROOF FIXINGS
LOW / MEDIUM WIND ZONE
Timber: class 4 12 x 65mm with neo washer and embossed washer
Steeltite: 12 x 65mm with neo washer and embossed washer
HIGH WIND ZONE
Timber: class 4 12 x 65mm with neo washer and embossed washer, approved profile’s metal washer and EPDM washer
Steeltite: 12 x 65mm with neo washer and embossed washer, approved profile’s metal washer and EPDM washer
WALL CLADDING
FIXINGS
Cladding fixing on 20mm. Every pan with 12 gauge class 4 screws with neo washers. H 3.1 Treated Battens
TRS 5 more cad files and specificationhttps://www.theroofingstore.co.nz/steel-roofing-and-cladding-profile-specifications