Technical Statement
Product Description
Scope of use
EFVM® is used to find defective workmanship and damage in the application of waterproofing membrane. This then allows the applicator to repair on the spot and handover a watertight membrane.
EFVM® is an approved testing as stated by Waterproofing Membrane Association Incorporated Torch on Code of Practise.
EFVM® tests ALL membranes apart from Butyl rubber membranes because of the Carbon contained in the make up of the product. (carbon absorbs electricity, not an isolator).
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause E2 External moisture: Performance E2.3.7(a)
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
EFVM® complies with E2 by ensuring the integrity waterproofing membrane is installed in accordance with NZBC.
Waterproofing Membrane Association Incorporated Torch on Code of Practice
6.5 Testing There are two methods of testing the integrity of a torch-on membrane after installation, either flood testing or electronic field testing. In both cases, after the testing has been carried out a written report confirming the integrity of the membrane must be supplied to the Main Contractor.
6.5.2 Electronic Field Testing Electric field testing works by passing a controlled electric current through the membrane with either a thin water film applied over the membrane or a pre-installed non-obtrusive metal grid under the membrane being the conductive medium. Any point of electric current leakage will indicate the location of a fault in the membrane system. This testing must be carried out by a trained technician.
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
Two Types of Substrate
Conductive - Concrete
EFVM® can be performed on the membrane application after the installation of the membrane. The concrete and reinforcing steel will allow an electrical connection if there is a breach in the membrane.
Installation requirements
-No installation of Vector Mesh required on a Concrete substrate
|
Date last validated:
03 February 2017 |
|
Date last updated:
03 February 2017 |