Technical Statement
Product Description
Scope of use
- Can be used with rigid air barrier systems – Fibre-cement sheet & plywood.
- Can be installed in very hot conditions
- Residential & commercial applications
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B2 Durability: Performance B2.3.1(b), B2.3.2
- Clause E2 External moisture: Performance E2.3.2
- Clause F2 Hazardous building materials: Performance F2.3.1
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
Designed to prevent air leakage and water penetration around window and door openings at framing junctions, and to keep any water that gets past the cladding, or through the joinery, from direct contact with the framing timber.
Installation requirements
- Must completely cover the joinery opening.
- The wrap is then cut on a 45 degree angle away from each corner of the opening so the flaps can be folded into the opening and secured to the interior face of the timber framing.
- The surface must be clean, dry and free from any surface contaminants such as dust and grease that may cause loss of adhesion.
- A 75mm wide x 150mm long sealing tape 'butterfly' must be installed at 45 degrees across the corner of the jamb/sill junction overlapping the corner by 3mm to create a seal at the corner of juction.
|
Date last validated:
07 July 2020 |
|
Date last updated:
07 July 2020 |