Technical Statement
Product Description
Scope of use
Roofing Industries Trimrib® roofing and wall cladding system for use on commercial and residential buildings within the following scope:
When used for roofing: Trimrib® may be used with a minimum roof gradient of 3 degrees.
When used as a wall cladding:
installed vertically or horizontally, Roofing Industries Trimrib to be fixed on a drained and ventilated cavity, where the risk score 7 - 20 calculation relies on the NZBC E2/AS1.
Trimrib® is available in clear sheeting (GRP) in matching profile.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.3(a), B1.3.3(b), B1.3.3(g), B1.3.3(h)
- Clause B2 Durability: Performance B2.3.1(b), B2.3.1(c)
- Clause C3 Fire affecting areas beyond the fire source: Performance C3.9
- Clause E2 External moisture: Performance E2.3.1, E2.3.2
- Clause G12 Water supplies: Performance G12.3.2
Notes
C Fire:
- ColorCote® Zinacore™ is rated as a Group 1-S when tested in accordance with ISO 5660:2002 Part 1 and Part 2.
- ColorCote® Magnaflow™ is rated as a Group 1-S when tested in accordance with ISO 5660:2002 Part 1 and Part 2
- ColorCote® Alumigard™ is rated as a Group 1-S when tested in accordance with ISO 5660:2002 Part 1 and Part 2
- Colorsteel® Maxx® is rated as a Group 1-S when tested in accordance with ISO 5660:2002 Part 1 and Part 2.
- Colorsteel® Endura® is rated as a Group 1-S when tested in accordance with ISO 5660:2002 Part 1 and Part 2.
G12 Drinking Water: ColorCote® Zinacore™ - Magnaflow™ - Alumigard™ and Colorsteel® Endura® - Maxx® - Altimate® samples tested in accordance with AS/NZS 4020:2005 passed the requirements for products in contact with drinking water.
Evidence
The product meets the requirements set out in the following documents, or relevant parts of cited standards within the documents:
Roofing Industries products meets the requirements set out in the following documents or relevant parts of the Building codes and cited standards.
- NZBC Clauses B2, E2, E3, New Zealand Metal Roof and Wall Cladding Code of Practice www.metalroofing.org.nz
- NZ Steel and Pacific Coilcoaters supplies coil to Roofing Industries:
- Test information available for our coil suppliers, and past history of in use of metal long run roof and wall cladding within New Zealand.
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
To comply with the performance clause of NZBC clause E2 roof cladding to be installed in accordance with:
- Acceptable solution E2/AS1
- NZMRM Code of Practice
- Roofing Industries Details and available on ‘www.roof.co.nz’,
- Roofing Industries specifications.
Roof cladding to be installed in accordance with acceptable solution E2:AS1 clause, Structure and table for the wind zone at the specific site location. For additional information refer to NZMRM Code of Practice for Maximum span and fastener requirements.
Installation requirements
Lonk to MRM Code of Practice
Link to NZ Steel Installers Guide
Maintenance requirements
Link to NZ Steel Maintenance Guide
Warrantees
Link to Colorsteel Environmental Categories
Link to Colorcote Environmental Categories
Environmental
Colorcote
Link to NZ Steel Environmental Product Declaration Guide
Environmental category literature available by request or the roof.co.nz website, or by contacting Roofing Industries, technical helpline 0800 844 822
Relationships
|
New Zealand Made |
|
Environmental Choice New Zealand |
|
Date last validated:
01 November 2021 |
|
Date last updated:
01 November 2021 |